3.00 
  • Heat pump model included
    • One stage system
    • Air and ground source 
    •  Space heating only
  • Auto-generated compressors. Specify cooling or heating capacity instead of selecting compressors
  • Groundwater cooling can be used as supplement to mechanical cooling (one stage systems only)
    •  Only ATES systems with full thermal balancing included
  • Instead of specifying the evaporation temperature, it is now possible to specify the evaporator size (for one stage system). I.e. the evaporation temperature is output from calculation.
  • Updated ZB and ZF compressor models from Copeland
  • Warnings and errors shown in detail on both monthly energy consumption diagram and summary table
  • Icon illustrating calculation state next to "Calculate" button (emphasize warnings) 
  • Plots changed so that weather data can be easily displayed
  •  Misc improvements and bug fixes...
2.31  - Added possibility to include water consumption (and rain water tank) in LCC calculation for cooling tower 
2.30 

- Bug fix so that new Dorin compressors are installed when updating an old version of PackCalc

- Changed month and day names so that they are in the same language as the rest of the program (English)

2.29 

- New Dorin range of subcritical compressors (SCC range) added

- New Dorin range of transcritical compressors (CD range) added

- Improved model of Cooling Tower developed by Danish Technological Institute and Vestas Aircoil

- Power consumption when using free cooling included

- Possible to specify charge for both high and low side in cascade systems when calculating CO2 emissions

- COP calculations for two-stage systems fixed (now condensing heat from low stage is not regarded useful when calculating overall COP)

- Several minor fixes and changes...

2.28 

- Load profiles from building simulation program BSim can now be imported. See appendix D in user manual.

- 60Hz Dorin CO2 compressors have been included

- Minor changes...

2.27 

- Change in calculation of capacity for transcritical compressor in subcritical design condition (change only affects the compressor selection - not the yearly calculation)
 2.26

- Bock transcritical compressors updated

- Dorin SCS compressors added

- Changes to userinterface so that users are presented to less options. This can be controlled in Options|Preferences menu

 2.25 First properly tested version 